DETERMINATION OF THE MAXIMUM TIME OF DISCONNECTION OF AN INDUCTION MOTOR FROM THE MAINS IN THE EVENT OF VOLTAGE FAILURE
DOI:
https://doi.org/10.30888/2709-2267.2023-21-01-022Keywords:
induction motor, torque, rotation speed, motor supply voltage, voltage dipAbstract
The work investigated the behavior of an induction motor when the supply voltage disappears and its value changes. Analysis of the results shows that the permissible time of voltage dip depends on the total moment of inertia of the moving parts, and to aMetrics
References
Mirafzal, B., Skibinski, G. L., & Tallam, R. M. Determination of parameters in the universal induction motor model. IEEE Transactions on Industry Applications, 2009, 45(1), 142-151.
O. Iegorov, O. Iegorova, O. Miroshnyk and O. Savchenko, “Improving the accuracy of determining the parameters of induction motors in transient starting modes”, ENERGETIKA, vol. 66, no. 1, 2020, pp. 15–23.
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. A survey of condition monitoring and protection methods for medium-voltage induction motors. IEEE Transactions on Industry Applications, 2010, 47(1), 34-46.
Finkelshtein V., Iegorov O., Maleev A. Comparison of characteristics of the converter-fed motor at supply from the single-phase network and from the source of the direct current. Електротехніка і електромеханіка. 2015. № 4. P. 15–19.
Iegorov O., Iegorova O., Kundenko M., Milenin A. Single-Phase Induction Motors Winding Parameters Optimization with Maximum Efficiency. 2020 IEEE Problems of Automated Electrodrive. Theory and Practice (PAEP). 21-25 Sept. 2020.
De Almeida, A. I., Ferreira, F. J., Busch, J. F., & Angers, P. Comparative analysis of IEEE 112-B and IEC 34-2 efficiency testing standards using stray load losses in low-voltage three-phase, cage induction motors. IEEE Transactions on industry applications, 2002, 38(2), 608-614.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Authors
This work is licensed under a Creative Commons Attribution 4.0 International License.